Search results for "Power rating"
showing 10 items of 15 documents
Investigation and reduction of losses on inverter-fed induction motors
2017
An electric motor is more effective and flexible when supplied by a frequency converter. The frequency converter not only produces the fundamental voltage but also a set of higher harmonics which cause additional losses in the motor. Losses in the frequency converter are normally neglected in the drive dimensioning due to insufficient data available from manufacturers. Motor's losses can be reduced by increasing the switching frequency of frequency converters. An increase of the switching frequency may result in higher losses in the frequency converter. This work investigates analytically and experimentally the dependence of the losses of modern motor and frequency converter on a switching …
Modelling and analysis of real-world wind turbine power curves: Assessing deviations from nominal curve by neural networks
2019
Abstract The power curve of a wind turbine describes the generated power versus instantaneous wind speed. Assessing wind turbine performance under laboratory ideal conditions will always tend to be optimistic and rarely reflects how the turbine actually behaves in a real situation. Occasionally, some aerogenerators produce significantly different from nominal power curve, causing economic losses to the promoters of the investment. Our research aims to model actual wind turbine power curve and its variation from nominal power curve. The study was carried out in three different phases starting from wind speed and related power production data of a Senvion MM92 aero-generator with a rated powe…
Feedback linearization control of wind turbine equipped with doubly fed induction generator
2017
This paper focuses on several control techniques of a wind turbine of rated power of about 1 MW. In particular, a wind generator equipped with an asynchronous doubly-fed induction machine has been considered and its dynamic model in MATLAB/SIMULINK environment has been implemented. Starting from this model the feedback linearization control has been derived, and several simulations have been carried out, with the aim of compare its dynamic performances with the classical field oriented control, and with the V/f control. The results allow us to conclude that a DFIG controlled by a feedback linearization technique ensures better dynamic performance.
Evaluation of performance and efficiency and type approval of an electrically assisted bicycle drive
2013
The diffusion of electrically assisted bicycles gives rise to the need of the evaluation of the performance and efficiency of the electric drive that supply it. In this paper, is presented a test bench for the estimation of the electric drive output torque under several speed and load conditions. Moreover, the test bench detects the electrical and mechanical parameters that allow to evaluate the electrical drive efficiencies. The test bench has been designed in agreement with the Directive 2002/24/EC of the European Parliament since it detects the maximum continuous rated power (that must be lower than 0.25 kW) and evaluates if the output is progressively reduced and finally cut off as the …
Effects of COVID19 pandemic on the Italian power system and possible countermeasures
2021
Abstract The paper analyses the dramatic effects of the first wave of the COVID-19 pandemic on the Italian power system, considering the impacts on load and generation, market issues and ancillary services provision. During the period between March and May 2020, the Italian scenario was considered as exemplary due to the large reduction of loads and thermal generation caused by the hard lockdown across the Country. Italy has experienced the most severe effects of pandemic in terms of increase of death rates and of pressure on the health system as well as severity of the countermeasures. As a domino effect, the total lockdown of one of the most industrialized countries in the world has creat…
Experimental EMF characterization of a secondary substation
2015
This paper presents the results of the experimental EMC characterization of a new medium/low voltage (MV/LV) secondary substation, which was developed in the framework of the research project "NEW CAB ELARC". It has two MV/LV transformers, with total rated power of 1000 kVA. To perform the experimental characterization, firstly an analysis was performed of the Italian and European standards recommendations. Different approaches were highlighted and the most appropriate procedures were identified for the measurement of the magnetic fields emissions, at power systems frequency (50 Hz) in steady-state conditions. A dedicated test lab was set up for the secondary substation characterization. Th…
Oil filled MV/LV Power Transformer Behavior in Narrow Band Power Line Communication Systems
2012
The aim of this paper is to characterize oil-filled power transformers in the narrow-band power-line communication (PLC) frequency range of 50-150 kHz. A new model is proposed for such type of a transformer, in the aforementioned frequency range of interest, in order to study its influence on the signal transmission and to investigate the possibility that the PLC signal can cross the power transformer itself. The new model is simpler than those previously proposed in literature, and it can be used in the whole frequency range available for NB PLC according to the CENELEC EN 50065-1 A-band. In order to validate the model, simulation and measurement results are compared for four oil-filled po…
Manufacturing tolerances effects on PV array energy production
2014
This paper investigates the tolerance effects of commercial photovoltaic modules in terms of electrical energy reduction of photovoltaic plants. Several commercial modules, having the same rated power, present different power tolerance values. A wide tolerance is an indicator of possible defects or differences in the production process and is responsible of remarkable reductions in the electricity production of photovoltaic plants. In this paper, thanks to the development of a suitable simulation tool, several simulations have been carried out, considering different tolerance and shading conditions for the PV array. Simulation results quantify the peak power value of the different plant con…
Economic analysis on dynamic photovoltaic systems in new Italian “feed in tariffs” context
2013
Dynamic photovoltaic generators, based on the application of solar-trackers, are able to give an increment to the electric energy production from solar source. Their realization and maintenance costs are certainly higher than those of fixed ones. In this paper the Authors propose a method to estimate the increment of electrical energy generation that must be guaranteed by a dynamic photovoltaic generator, so as its realization could be more favorable with respect to that of a fixed generator one with the same rated power. This method, developed by means of classical economic indexes like the Pay-Back-Period and the Net Present Value, takes in to account the economic incentives for the PV sy…
A discussion on variants of stand-alone electric powerplant equipped with transverse flux generators
2015
The paper discussed several designed variants of TFG with different number of poles, speed and dimensional coefficients starting from two base module variants with a rated power of 8kW and 11 kW respectively. The proposed layout came from reluctance one and it is suitable to equipped stand-alone electric power plant being a proper solution for isolated farms. The influence of large number of poles on torque density values obtained at low rotational speed is discussed in paper.